Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diabetes Technol Ther ; 25(5): 315-323, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36826996

RESUMO

Objective: We evaluated the safety and feasibility of open-source automated insulin delivery AndroidAPS in adolescents and young adults with type 1 diabetes (T1D) and compared its efficacy in three different scenarios: hybrid closed loop (HCL) with meal boluses, meal announcement only (MA), and full closed loop (FCL). Research Design and Methods: In an open-label, prospective, randomized crossover trial (clinicaltrials.gov NCT04835350), 16 adolescents with T1D (10 females) with mean age of 17 years (range 15-20), glycated hemoglobin 56 mmol/mol (range 43-75), and mean duration of diabetes 5.9 years (9-15) underwent three distinct 3-day periods of camp living, comparing the above-mentioned scenarios of AndroidAPS. We used modified and locked version of AndroidAPS 3.1.03, which was called Pancreas4ALL for study purposes. The order of MA and FCL periods was assigned randomly. The primary endpoints were feasibility and safety of the system represented by percentage of time of glucose control by the system and time in hypoglycemia below 3 mmol/L. Results: The glycemia was controlled by the system 95% time of the study and the proportion of time below 3 mmol/L did not exceed 1% over the whole study period (0.72%). The HCL scenario reached significantly higher percentage of time below 3 mmol/L (HCL 1.05% vs. MA 0.0% vs. FCL 0.0%; P = 0.05) compared to other scenarios. No difference was observed among the scenarios in the percentage of time between 3.9 and 10 mmol/L (HCL 83.3% vs. MA 79.85% vs. FCL 81.03%, P = 0.58) corresponding to mean glycemia (HCL 6.65 mmol/L vs. MA 7.34 mmol/L vs. FCL 7.05 mmol/L, P = 0.28). No difference was observed in the mean daily dose of insulin or in the daily carbohydrate intake. No serious adverse event occurred during the study period. Conclusions: Our pilot study showed that FCL might be a realistic mode of treatment for people with T1D.


Assuntos
Diabetes Mellitus Tipo 1 , Insulina , Feminino , Adolescente , Adulto Jovem , Humanos , Adulto , Insulina/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes , Projetos Piloto , Estudos Prospectivos , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico , Estudos Cross-Over , Glicemia
2.
Pediatr Diabetes ; 22(4): 594-604, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33576551

RESUMO

OBJECTIVE: Data on closed loop systems in young children with type 1 diabetes (T1D) are limited. We tested the efficacy and safety of an open-source, do-it-yourself automated insulin delivery system AndroidAPS in preschool and school-aged children. RESEARCH DESIGN AND METHODS: This retrospective study analyzed diabetes control in 18 preschool (3-7 years) and 18 school-aged children (8-14 years) with T1D who switched from a sensor-augmented pump (SAP) to AndroidAPS. We compared the CGM parameters and HbA1c levels 3 months before and 6 months after the initiation of AndroidAPS therapy and evaluated frequency of severe adverse events during AndroidAPS use, the most frequent reasons for its interruption, and the experience and psychosocial benefits of AndroidAPS use. RESULTS: General glycemic control was significantly improved after the switch from SAP to AndroidAPS. Time in range (TIR) increased in both preschool (70.8%-78.6%, p = 0.004) and school-aged children (77.2%-82.9%, p < 0.001), whereas HbA1c levels decreased (preschool children 53.8-48.5 mmol/mol, p < 0.001; school-aged children 52.6-45.1 mmol/mol, p = 0.001). Time spent in range of 3.0-3.8 mmol/L increased slightly in school children (2.6%-3.8%, p = 0.040), but not in preschool children (3.0%-3.0%, p = 0.913). Time spent at <3 mmol/L remained unchanged in both preschool (0.95%-0.67%, p = 0.432) and school-aged children (0.8%-0.8%, p = 1.000). No episodes of severe hypoglycemia or DKA and significant improvement of quality of life were reported by AndroidAPS users. CONCLUSIONS: AndroidAPS seems effective for T1D control both in preschool and school-age children but further validation by prospective studies is necessary.


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Adolescente , Fatores Etários , Glicemia/metabolismo , Criança , Pré-Escolar , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Masculino , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
3.
Diabetes Technol Ther ; 22(2): 112-120, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31769699

RESUMO

Objective: Safety data on Do-It-Yourself Artificial Pancreas Systems are missing. The most widespread in Europe is the AndroidAPS implementation of the OpenAPS algorithm. We used the UVA/Padova Type 1 Diabetes Simulator to in silico test safety and efficacy of this algorithm in different scenarios. Methods: We tested five configurations of the AndroidAPS algorithm differing in aggressiveness and patient's interaction with the system. All configurations were tested with insulin sensitivity variation of ±30%. The most promising configurations were tested in real-life scenarios: over- and underestimated bolus by 50%, bolus delivered 15 min before meal, and late bolus delivered 15 min after meal. Continuous Glucose Monitoring (CGM) time in ranges (TIRs) metrics were used to assess the glycemic control. Results: In silico testing showed that open-source closed-loop system AndroidAPS works effectively and safely. The best results were reached if AndroidAPS algorithm worked with microboluses and when half of calculated bolus was issued (mean glycemia 131 mg/dL, SD 27 mg/dL, TIR 91%, time between 54 and 70 mg/dL <1%, and low blood glucose index even <1). The meal bolus over- and underestimation as well as late bolus did not affect the TIR and, importantly, the time between 54 and 70 mg/dL. Conclusion: In silico testing proved that AndroidAPS implementation of the OpenAPS algorithm is safe and effective, and it showed a great potential to be tested in prospective home setting study.


Assuntos
Glicemia/análise , Simulação por Computador , Diabetes Mellitus Tipo 1/sangue , Teste de Materiais/métodos , Pâncreas Artificial , Algoritmos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Segurança de Equipamentos , Humanos , Sistemas de Infusão de Insulina , Resistência à Insulina , Refeições , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...